FHWA Highway Safety Programs

Safety Eligibility Letter WZ-95

Hardware Type:
Work Zone Devices
Code:
WZ-95
Date:
Testing Criteria:
NCHRP 350
Manufacturer:
United Rentals
Device Description:
High SafetyCor X-Tube Speed Limit Sign #129
View PDF:
wz95.pdf (74.2 KB)

Safety Eligibility Letter WZ-104

DOT logo
U.S. Department
of Transportation
Federal Highway
Administration
400 Seventh St., S.W.
Washington, D.C. 20590

Refer To: HSA-10/WZ-95

Mr. Henry A. Ross, Director
Sales and Marketing
United Rentals Highway Technologies
880 North Addison Road
P.O. Box 7050
Villa Park, IL 60181-7050

Dear Mr. Ross:

Thank you for your letter of June 6 requesting Federal Highway Administration (FHWA) acceptance of your company’s High SafetyCor X-Tube Speed Limit Sign as crashworthy traffic control devices for use in work zones on the National Highway System (NHS). Accompanying your letter was a report of crash testing conducted by E-Tech Testing Services along with a video of the tests. You requested that we find this device acceptable for use on the NHS under the provisions of National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”

Introduction
The FHWA guidance on crash testing of work zone traffic control devices is contained in two memoranda. The first, dated July 25, 1997, titled “INFORMATION: Identifying Acceptable Highway Safety Features,” established four categories of work zone devices: Category I devices were those lightweight devices which could be self-certified by the vendor, Category II devices were other lightweight devices which needed individual crash testing, Category III devices were barriers and other fixed or massive devices also needing crash testing, and Category IV devices were trailer mounted lighted signs, arrow panels, etc. The second guidance memorandum was issued on August 28, 1998, and is titled “INFORMATION: Crash Tested Work Zone Traffic Control Devices.” This later memorandum lists devices that are acceptable under Categories I, II, and III.

A brief description of the device for which you are requesting acceptance follows:

High SafetyCor X-Tube Speed Limit Sign is a lightweight portable sign support made up of 44.5 mm square “X-Tube” PVC extrusions. The X-Tube uprights slip into 57.2 mm perforated tube steel sockets welded to a support base. The support base is made up of 50.8 mm x 50.8 mm x 4.8 mm thick steel angle iron.

The sign stand system features a two high arrangement of 914 mm wide rectangular signs made of 10.2 mm thick “SafetyCor”, an unfilled polypropylene copolymer corrugated plastic sheeting material. Each sign is bolted to the uprights with four 7.9 mm diameter ASTM A307 hex

fasteners and special 38.1 mm outside diameter rubber encased flat washers that increase the bearing area and help to prevent sign damage when the stands are stacked. When deployed the bottom of the lowest sign is nominally 1516 mm above the ground, and the overall height is
3662 mm to the top of the highest sign. As tested, the stands weighed 36.1 kg, and had four 18 kg sand bags as ballast. The four bags were placed at the ends of the supports.

Testing
Full-scale automobile testing was conducted on your company’s devices. Two stand-alone examples of the device were tested in tandem, one head-on and the next placed six meters downstream turned at 90 degrees, as called for in our guidance memoranda. The complete device as tested is shown in Enclosure 1.

The crash test is summarized in the table below:

Test Number 05-3721-013
Test Article High SafetyCor X-Tube Speed Limit Sign
Height to Bottom of Sign 1516 mm
Height to Top of Lights 3662 mm
Flags or lights None
Test Article Mass (each) 36.1 kg
Vehicle Inertial Mass 823 kg
Impact Speed, Head-on 101.1 km/hr
Impact Speed, 90 Deg. 97.7 km/hr
Velocity Change, Head-on 0.94 m/s
Velocity Change, 90 deg. 0.94 m/c
Vehicle crush Slight damage to bumper, grill, hood, windshield
Occupant Compart. Intrusion None
Windshield Damage General cracking, some broken glass in occupant compartment

Findings
Damage was limited to cosmetic sheet metal damage, with moderate cracking of the windshield. There were no holes or deformation of the windshield glass, nor was the damage extensive enough to impair the driver’s visibility. The results of the testing met the FHWA requirements and, therefore, the devices described above and shown in the enclosed drawings for reference are acceptable for use as Test Level 3 devices on the NHS under the range of conditions tested, when proposed by a State.

Please note the following standard provisions which apply to FHWA letters of acceptance:

  • Our acceptance is limited to the crashworthiness characteristics of the devices and does not cover their structural features, nor conformity with the Manual on Uniform Traffic Control Devices.
  • Any changes that may adversely influence the crashworthiness of the device will require a new acceptance letter.
  • Should the FHWA discover that the qualification testing was flawed, that in-service performance reveals unacceptable safety problems, or that the device being marketed is significantly different from the version that was crash tested, it reserves the right to modify or revoke its acceptance.
  • You will be expected to supply potential users with sufficient information on design and installation requirements to ensure proper performance.
  • You will be expected to certify to potential users that the hardware furnished has essentially the same chemistry, mechanical properties, and geometry as that submitted for acceptance, and that they will meet the crashworthiness requirements of FHWA and NCHRP Report 350.
  • To prevent misunderstanding by others, this letter of acceptance, designated as number WZ-95 shall not be reproduced except in full. This letter, and the test documentation upon which this letter is based, is public information. All such letters and documentation may be reviewed at our office upon request.
  • United Rentals work zone traffic control devices may include patented components and if so are considered "proprietary." The use of proprietary work zone traffic control devices in Federal-aid projects is generally of a temporary nature. They are selected by the contractor for use as needed and removed upon completion of the project. Under such conditions they can be presumed to meet requirement "a" given below for the use of proprietary products on Federal-aid projects. On the other hand, if proprietary devices are specified for use on Federal-aid projects, except exempt, non-NHS projects, they: (a) must be supplied through competitive bidding with equally suitable unpatented items; (b) the highway agency must certify that they are essential for synchronization with existing highway facilities or that no equally suitable alternative exists or; (c) they must be used for research or for a distinctive type of construction on relatively short sections of road for experimental purposes. Our regulations concerning proprietary products are contained in Title 23, Code of Federal Regulations, Section 635.411, a copy of which is enclosed.
  •   Sincerely yours,

     

    Frederick G. Wright, Jr.
    Program Manager, Safety

    Enclosure