USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation
FHWA Highway Safety Programs

Safety Eligibility Letter WZ-238

Hardware Type:
Work Zone Devices
Code:
WZ-238
Date:
Testing Criteria:
NCHRP 350
Manufacturer:
Work Area Protection
Device Description:
WZS12, WZS12-S, WZX60-SL
View PDF:
wz238.pdf (1.09 MB)
Skip to contentSkip to contentUnited States Department of Transportation - Federal Highway Administration FHWA HomeFeedback


DOT logo
U.S. Department of Transportation

Federal Highway Administration

400 Seventh St., S.W.
Washington, D.C. 20590

June 15, 2006

Refer to: HSA-10/WZ-238

Mr. Jeffery D. Smith
Work Area Protection Corporation
P.O. Box 4087
2500 Production Drive
St. Charles, Illinois 60174

Dear Mr. Smith :

Thank you for your letter of February 17, 2006, requesting the Federal Highway Administration (FHWA) acceptance of your company's WZS12, WZS12-S, and WZX60-SL portable sign sands as crashworthy traffic control devices for use in work zones on the National Highway System (NHS). Your letter included a list of crashworthy signs manufactured by another vendor with whom you have reached agreement to sell under your name. You requested that we find these devices acceptable for use on the NHS under the provisions of National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”

Introduction
The FHWA guidance on crash testing of work zone traffic control devices is contained in two memoranda. The first, dated July 25, 1997, titled “INFORMATION: Identifying Acceptable Highway Safety Features,” established four categories of work zone devices: Category I devices are those lightweight devices which are to be self-certified by the vendor, Category II devices are other lightweight devices which need individual crash testing but with reduced instrumentation, Category III devices are barriers and other fixed or heavy devices also needing crash testing with normal instrumentation, and Category IV devices are trailer mounted lighted signs, arrow panels, etc. for which crash testing requirements have not yet been established. The second guidance memorandum was issued on August 28, 1998, and is titled “INFORMATION: Crash Tested Work Zone Traffic Control Devices.” This later memorandum lists devices that are acceptable under Categories I, II, and III. Our new acceptance process was outlined in our memorandum “FHWA Hardware Acceptance Procedures – Category 2 Work Zone Devices” dated November 11, 2005.

The following sign stand was crash tested by the Texas Transportation Institute and acknowledged as crashworthy in the FHWA acceptance letter WZ-67 dated January 26, 2001.

(Tested sign): A portable work zone sign fabricated with square steel tubing is used to support a 1220 x 1220 mm vinyl roll-up sign panel that is stiffened with 32 mm by 8 mm rectangular cross section fiberglass straps. The mast consists of a 1500 mm long, 32 mm square, 2.5 mm thick steel tube with a 150 mm long, 38 mm square, 2.5 mm thick tube section at the top for sign attachment. Four telescoping legs were fabricated from 25 mm and 30 mm square tubing. The inner legs were 470 mm long while the outer legs were 1168 mm long. The bottom of the roll-up sign was mounted approximately 1.5 m above the ground level. Details of the roll-up sign and stand (in English units) are shown in the enclosed drawing.

You requested acceptance of the WZS60-SL, which is a spring-loaded version of the same stand. You also provided drawings for the model WZS12 stand. This four-legged stand supports a roll-up sign at 305 mm above the pavement. The metal structure of the stand rises no higher than that necessary to secure the bottom of the fiberglass ribs supporting the roll-up sign, as shown on the enclosed drawings. Your model number WZS12S is a spring loaded version of this low stand.

Findings
The tested stand contacted the windshield and caused only minor damage and no penetration of the windshield. Therefore, your stand model number WZS60-SL, which is identical to the tested stand except for the use of a spring mechanism at the base, is acceptable for use.

The WZS12 and WZS12-SL stands are both “compact” sign stands under our definition, as detailed in the “Questions and Answers” portion of the FHWA acceptance letter WZ-85, a copy of which is enclosed for your information and use. Compact sign stands supporting
roll-up signs with fiberglass spreaders as detailed in WZ-85 do not require individual crash testing.

The results of the testing of the basic model sign stand met the FHWA requirements. As the manufacturer will fabricate them to the same specifications, the devices described above and detailed in the enclosed drawings are acceptable for use on the NHS under the range of conditions tested, when proposed by a State.

Please note the following standard provisions that apply to the FHWA letters of acceptance:

  • Our acceptance is limited to the crashworthiness characteristics of the devices and does not cover their structural features, or conformity with the Manual on Uniform Traffic Control Devices.
  • Any changes that may adversely influence the crashworthiness of the device will require a new acceptance letter.
  • Should the FHWA discover that the qualification testing was flawed, that in-service performance reveals unacceptable safety problems, or that the device being marketed is significantly different from the version that was crash tested, it reserves the right to modify or revoke its acceptance.

  • You will be expected to supply potential users with sufficient information on design and installation requirements to ensure proper performance.
  • You will be expected to certify to potential users that the hardware furnished has essentially the same chemistry, mechanical properties, and geometry as that submitted for acceptance, and that they will meet the crashworthiness requirements of the FHWA and the NCHRP Report 350.
  • To prevent misunderstanding by others, this letter of acceptance, designated as number WZ-238 shall not be reproduced except in full. This letter, and the test documentation upon which this letter is based, is public information. All such letters and documentation may be reviewed at our office upon request.
  • The subject portable sign stands are patented devices and considered "proprietary." The use of proprietary work zone traffic control devices in Federal-aid projects is generally of a temporary nature. They are selected by the contractor for use as needed and removed upon completion of the project. Under such conditions they can be presumed to meet requirement "a" given below for the use of proprietary products on Federal-aid projects. On the other hand, if proprietary devices are specified by a highway agency for use on Federal-aid projects: (a) they must be supplied through competitive bidding with equally suitable unpatented items; (b) the highway agency must certify that they are essential for synchronization with existing highway facilities or that no equally suitable alternative exists; or (c) they must be used for research or for a distinctive type of construction on relatively short sections of road for experimental purposes. Our regulations concerning proprietary products are contained in Title 23, Code of Federal Regulations, Section 635.411, a copy of which is enclosed.
  • This acceptance letter shall not be construed as authorization or consent by the FHWA to use, manufacture, or sell any patented device for which the applicant is not the patent holder. The acceptance letter is limited to the crashworthiness characteristics of the candidate device, and the FHWA is neither prepared nor required to become involved in issues concerning patent law. Patent issues, if any, are to be resolved by the applicant.

Sincerely yours,

/Original Signed by/
John R. Baxter, P.E.
Director, Office of Safety Design
Office of Safety

Enclosures


Safety Home | FHWA Home | Feedback