Safety Eligibility Letter CC-61A

Hardware Type:
Barrier Terminals and Crash Cushions
Code:
CC-61A
Date:
Testing Criteria:
NCHRP 350
Manufacturer:
Midwest Roadside Safety Facility
Device Description:
Conditional acceptance for bolted-steel posts for SKT-350
View PDF:
cc61a.pdf (299.8 KB)

October 30, 2002

HSA-10/CC-61A

Dean L. Sicking, PhD., P.E.
Director, Midwest Roadside safety Facility
W. 328.1 Nebraska Hall
P.O. Box 880529
Lincoln, NE 68588-0529

Dear Dr. Sicking:

In your July 24 letter to Mr. Richard Powers of my staff, you requested formal acceptance of a two-piece bolted breakaway post for use with the SKT and FLEAT w-beam guardrail terminals.  The breakaway posts originally tested and accepted for use with these terminals used a one-piece post with a plug welded breakaway design.  You presented both static analyses of the bolted design vs. the original plug welded design as well as the results of low-speed bogie tests on individual posts.  The layout of the SKT terminal using the modified posts is shown on Enclosure 1. Details for posts 1 and 2 and for the line posts (posts 3-8) are shown on Enclosure 2.

Although your analyses and component testing showed comparable strong- and weak-axis performance of individual posts, I remain concerned about the posts' equivalency in a redirective impact into the side of the system where the posts are not hit at right angles to either axis and the bolts may not be loaded equally or uniformly.  Consequently, I will allow conditional use of the bolted post design with the SKT terminal, but will withhold acceptance of its use with the FLEAT (with its greater flare angle) until successful completion of NCHRP Report 350 test 3-35 on a FLEAT with its full 4-foot offset.  I understand you plan to conduct this test in early 2003.  In the interim, the field performance of any SKT terminals using the bolted post design should be monitored to verify acceptable crash performance.

Sincerely yours,