USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation
FHWA Highway Safety Programs

Safety Eligibility Letter CC-42A

Hardware Type:
Barrier Terminals and Crash Cushions
Code:
CC-42A
Date:
Testing Criteria:
NCHRP 350
Manufacturer:
Energy Absorption Systems, Inc.
Device Description:
QuadGuard w/ 10-degree side-panel flare
View PDF:
cc42a.pdf (357.49 KB)
Skip to contentUnited States Department of Transportation - Federal Highway Administration FHWA HomeFeedback

December 10, 2003

Refer to: HSA-10/CC42-A

Barry D. Stephens, P.E.
Senior Vice President of Engineering
Energy Absorption Systems, Incorporated
3617 Cincinnati Avenue
Rocklin, California  95765

Dear Mr. Stephens:

In his July 16, 1997, letter to Mr. J. M. Essex, Mr. Dwight A. Horne accepted a 6-bay QuadGuard designed to shield an obstacle up to 2286-mm wide (QuadGuard-Wide) for use on the National Highway System (NHS).  With an effective attenuator length of 6.7 m, this design resulted in a maximum side panel flare of 6 degrees.

Your November 15, 2003, letter to Mr. Richard Powers of my staff requested acceptance of a 6-bay QuadGuard-Wide attenuator with a side panel flare of 10 degrees designed to shield an obstacle 3.0-m wide (as shown in Enclosure 1).  To support this request, you ran two tests to verify the crash performance of the wider design.  Members of my staff had previously agreed that this minimum test matrix comprised the most critical tests for the wider QuadGuard and that the remaining tests could be waived.  The summary results of the two successful tests (NCHRP Report 350 tests 3-32 and 3-38) are shown in Enclosures 2 and 3.  To meet the Report 350 occupant risk parameters for test 3-32, a lightweight front diaphragm was designed and used in that test.  This design is shown as Enclosure 4.

Based on staff review of the tests you conducted, I agree that 6-bay (or longer) QuadGuard units with a side panel flare not to exceed 10 degrees may be used on the NHS as test level 3 attenuators when the lightweight front diaphragm is used.  For obstacles wider than 3.0 m, the 10-degree angle may be extended by adding increasingly wider diaphragms to the attenuator or, preferably, by continuing the same flare with a crashworthy transition connecting the back corners of the QuadGuard to the shielded obstacle.

Sincerely yours,

                                                                        /Original signed by/  

John R. Baxter, P.E.
Director, Office of Safety Design
Office of Safety

4 Enclosures


 

Safety Home | FHWA Home | Feedback
FHWA
United States Department of Transportation - Federal Highway Administration